The Model BV54 Brodie Rate of Flow Control
Valve is normally opened and designed to
maintain a controlled flow rate within +/-2%.
The pilot is balanced, single seated valve with
large ports and will operate on a differential as
low as 5 psi (34.5 kPa).
Features include
The Model BV54 valve is pilot operated and
operates on a balanced piston principle, spring
biased to a closed position. Pressure differential
overcomes the force of the spring, causing the
main valve to open and establish flow. The Rate
of Flow (Flow Limiting) Valve is normally open
and throttles toward a closed position on
increasing differential pressure.
The Model BV54 is normally used to control flow
rate through a metering device; however, it can be
utilized in any application requiring accurate,
dependable flow control.
The “AP” Option valve cylinder incorporates a
combination of seals and o-ring materials to provide optimum performance in aggressive
product applications. Specify “AP” Option at time
of order when valve is to be used on products
which may affect standard seals.