Skip to main content

Product Search

MV82 Insertion Multivariable Mass Vortex Flowmeter

Test Product

PanaFlow MV82’s multivariable design consists of a vortex shedding velocity sensor, an RTD temperature sensor and a solid state pressure transducer that measures the mass flow rate of steam, gases and liquids.

Features include

  • Multivariable Vortex meter – flow, press, temp, flow computer
  • Liquid, Gas, Steam & Energy flow measurement
  • Vol flow & Mass flow options (MV82-V/VT/VTP & Energy Metering)
  • Accuracy (Liq): +/- 1.2% Mass flow / +/- 1.5% Vol flow
  • Accuracy (Gas & Steam): +/- 1.5% Mass flow / +/- 2% Vol flow
  • Sizes: 2” to 72” – easy to retrofit – same unit all OD’s
  • Compression – 2” NPT & Flanged ANSI 150,300 & 600
  • Packing Gland – 2” NPT & Flanged ANSI 150,300 & 600
  • Fixed or Removable Retractable (HOT/COLD Tap)
  • Temp: -40 to +260 degC (HT Option +400 degC)
  • Wetted parts: 316SS & PTFE / Graphite
  • Straight Run: 10-25 Upstream / 5 Downstream
  • Integral or Remote Transmitter (8m or 16m)
  • LCD Display & Push buttons
  • 1 x 4 to 20mA HART & Scaled pulse (Loop Powered) & 1 x Limit
  • 3 x 4 to 20mA HART (V/P/T) & Scaled pulse & 3 x Limits
  • ATEX Exd IIB
Download a datasheet

Regional Focus

We use cookies to monitor site usage so we can make improvements to your experience. Is that OK with you?

Yes Tell me more